Τετάρτη 5 Απριλίου 2017

Cochlear Implantation in Cases of Unilateral Hearing Loss: Initial Localization Abilities.

wk-health-logo.gif

Objectives: The present study evaluated early auditory localization abilities of cochlear implant (CI) recipients with normal or near-normal hearing (NH) in the contralateral ear. The goal of the study was to better understand the effect of CI listening experience on localization in this population. Design: Twenty participants with unilateral hearing loss enrolled in a prospective clinical trial assessing outcomes of cochlear implantation (ClinicalTrials.gov Identifier: NCT02203305). All participants received the MED-EL Standard electrode array, were fit with an ear-level audio processor, and listened with the FS4 coding strategy. Localization was assessed in the sound field using an 11-speaker array with speakers uniformly positioned on a horizontal, semicircular frame. Stimuli were 200-msec speech-shaped noise bursts. The intensity level (52, 62, and 72 dB SPL) and sound source were randomly interleaved across trials. Participants were tested preoperatively, and 1, 3, and 6 months after activation of the audio processor. Performance was evaluated in two conditions at each interval: (1) unaided (NH ear alone [NH-alone] condition), and (2) aided, with either a bone conduction hearing aid (preoperative interval; bone conduction hearing aid + NH condition) or a CI (postoperative intervals; CI + NH condition). Performance was evaluated by comparing root-mean-squared (RMS) error between listening conditions and between measurement intervals. Results: Mean RMS error for the soft, medium, and loud levels were 66[degrees], 64[degrees], and 69[degrees] in the NH-alone condition and 72[degrees], 66[degrees], and 70[degrees] in the bone conduction hearing aid + NH condition. Participants experienced a significant improvement in localization in the CI + NH condition at the 1-month interval (38[degrees], 35[degrees], and 38[degrees]) as compared with the preoperative NH-alone condition. Localization in the CI + NH condition continued to improve through the 6-month interval. Mean RMS errors were 28[degrees], 25[degrees], and 28[degrees] in the CI + NH condition at the 6-month interval. Conclusions: Adult CI recipients with normal or near-normal hearing in the contralateral ear experienced significant improvement in localization after 1 month of device use, and continued to improve through the 6-month interval. The present results show that binaural acclimatization in CI users with unilateral hearing loss can progress rapidly, with marked improvements in performance observed after only 1 month of listening experience. Copyright (C) 2017 Wolters Kluwer Health, Inc. All rights reserved.

from #Audiology via xlomafota13 on Inoreader http://ift.tt/2nWjeIi
via IFTTT

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου