Δευτέρα 11 Ιανουαρίου 2016

Mandarin Tone and Vowel Recognition in Cochlear Implant Users: Effects of Talker Variability and Bimodal Hearing.

Objectives: For cochlear implant (CI) users with residual low-frequency acoustic hearing in the nonimplanted ear, bimodal hearing combining the use of a CI and a contralateral hearing aid (HA) may provide more salient talker voice cues than CI alone to handle the variability of talker identity across trials. This study tested the effects of talker variability, bimodal hearing, and their interaction on response accuracy and time of CI users' Mandarin tone, vowel, and syllable recognition (i.e., combined Mandarin tone and vowel recognition in this study). Design: Fifteen prelingually deafened native Mandarin-speaking CI users (at age 20 or lower) participated in this study. Four talkers each produced six Mandarin single-vowel syllables in four lexical tones. The stimuli were presented in quiet via a single loudspeaker. To study the effects of talker variability, Mandarin tone, vowel, and syllable recognition was tested in two presentation conditions: with stimuli blocked according to talker (blocked-talker condition) or mixed across talkers from trial to trial (mixed-talker condition). To explore the effects of bimodal hearing, two processor conditions were tested: CI alone or CI + HA. The cumulative response time was recorded as an indirect indicator of the cognitive load or listening effort in each condition. The correlations were computed between demographic/hearing factors (e.g., hearing thresholds in the nonimplanted ear) and bimodal performance/benefits (where bimodal benefits refer to the performance differences between CI alone and CI + HA). Results: Mandarin tone recognition with both CI alone and CI + HA was significantly poorer in the mixed-talker condition than in the blocked-talker condition, while vowel recognition was comparable in the two presentation conditions. Bimodal hearing significantly improved Mandarin tone recognition but not vowel recognition. Mandarin syllable recognition was significantly affected by both talker variability and bimodal hearing. The cumulative response time significantly reduced with CI + HA compared with CI alone, but remained invariant with respect to talker variability. There was no interaction between talker variability and bimodal hearing for any performance measure adopted in this study. Correlation analyses revealed that the bimodal performance and benefits in Mandarin tone, vowel, and syllable recognition could not be predicted by the hearing thresholds in the nonimplanted ear or by the demographic factors of the participants. Conclusions: Talker variability from trial to trial significantly degraded Mandarin tone and syllable recognition performance in both the CI alone and CI + HA conditions. While bimodal hearing did not reduce the talker variability effects on Mandarin tone and syllable recognition, generally better Mandarin tone and syllable recognition performance with shorter response time (an indicator of less listening effort) was observed when a contralateral HA was used in conjunction with the CI. On the other hand, vowel recognition was not significantly affected by either talker variability or bimodal hearing, because ceiling effects could not be counted out of the vowel recognition results. Copyright (C) 2016 Wolters Kluwer Health, Inc. All rights reserved.

from #Audiology via ola Kala on Inoreader http://ift.tt/1K9uioP
via IFTTT

Mandarin Tone and Vowel Recognition in Cochlear Implant Users: Effects of Talker Variability and Bimodal Hearing.

Objectives: For cochlear implant (CI) users with residual low-frequency acoustic hearing in the nonimplanted ear, bimodal hearing combining the use of a CI and a contralateral hearing aid (HA) may provide more salient talker voice cues than CI alone to handle the variability of talker identity across trials. This study tested the effects of talker variability, bimodal hearing, and their interaction on response accuracy and time of CI users' Mandarin tone, vowel, and syllable recognition (i.e., combined Mandarin tone and vowel recognition in this study). Design: Fifteen prelingually deafened native Mandarin-speaking CI users (at age 20 or lower) participated in this study. Four talkers each produced six Mandarin single-vowel syllables in four lexical tones. The stimuli were presented in quiet via a single loudspeaker. To study the effects of talker variability, Mandarin tone, vowel, and syllable recognition was tested in two presentation conditions: with stimuli blocked according to talker (blocked-talker condition) or mixed across talkers from trial to trial (mixed-talker condition). To explore the effects of bimodal hearing, two processor conditions were tested: CI alone or CI + HA. The cumulative response time was recorded as an indirect indicator of the cognitive load or listening effort in each condition. The correlations were computed between demographic/hearing factors (e.g., hearing thresholds in the nonimplanted ear) and bimodal performance/benefits (where bimodal benefits refer to the performance differences between CI alone and CI + HA). Results: Mandarin tone recognition with both CI alone and CI + HA was significantly poorer in the mixed-talker condition than in the blocked-talker condition, while vowel recognition was comparable in the two presentation conditions. Bimodal hearing significantly improved Mandarin tone recognition but not vowel recognition. Mandarin syllable recognition was significantly affected by both talker variability and bimodal hearing. The cumulative response time significantly reduced with CI + HA compared with CI alone, but remained invariant with respect to talker variability. There was no interaction between talker variability and bimodal hearing for any performance measure adopted in this study. Correlation analyses revealed that the bimodal performance and benefits in Mandarin tone, vowel, and syllable recognition could not be predicted by the hearing thresholds in the nonimplanted ear or by the demographic factors of the participants. Conclusions: Talker variability from trial to trial significantly degraded Mandarin tone and syllable recognition performance in both the CI alone and CI + HA conditions. While bimodal hearing did not reduce the talker variability effects on Mandarin tone and syllable recognition, generally better Mandarin tone and syllable recognition performance with shorter response time (an indicator of less listening effort) was observed when a contralateral HA was used in conjunction with the CI. On the other hand, vowel recognition was not significantly affected by either talker variability or bimodal hearing, because ceiling effects could not be counted out of the vowel recognition results. Copyright (C) 2016 Wolters Kluwer Health, Inc. All rights reserved.

from #Audiology via xlomafota13 on Inoreader http://ift.tt/1K9uioP
via IFTTT

Mandarin Tone and Vowel Recognition in Cochlear Implant Users: Effects of Talker Variability and Bimodal Hearing.

Objectives: For cochlear implant (CI) users with residual low-frequency acoustic hearing in the nonimplanted ear, bimodal hearing combining the use of a CI and a contralateral hearing aid (HA) may provide more salient talker voice cues than CI alone to handle the variability of talker identity across trials. This study tested the effects of talker variability, bimodal hearing, and their interaction on response accuracy and time of CI users' Mandarin tone, vowel, and syllable recognition (i.e., combined Mandarin tone and vowel recognition in this study). Design: Fifteen prelingually deafened native Mandarin-speaking CI users (at age 20 or lower) participated in this study. Four talkers each produced six Mandarin single-vowel syllables in four lexical tones. The stimuli were presented in quiet via a single loudspeaker. To study the effects of talker variability, Mandarin tone, vowel, and syllable recognition was tested in two presentation conditions: with stimuli blocked according to talker (blocked-talker condition) or mixed across talkers from trial to trial (mixed-talker condition). To explore the effects of bimodal hearing, two processor conditions were tested: CI alone or CI + HA. The cumulative response time was recorded as an indirect indicator of the cognitive load or listening effort in each condition. The correlations were computed between demographic/hearing factors (e.g., hearing thresholds in the nonimplanted ear) and bimodal performance/benefits (where bimodal benefits refer to the performance differences between CI alone and CI + HA). Results: Mandarin tone recognition with both CI alone and CI + HA was significantly poorer in the mixed-talker condition than in the blocked-talker condition, while vowel recognition was comparable in the two presentation conditions. Bimodal hearing significantly improved Mandarin tone recognition but not vowel recognition. Mandarin syllable recognition was significantly affected by both talker variability and bimodal hearing. The cumulative response time significantly reduced with CI + HA compared with CI alone, but remained invariant with respect to talker variability. There was no interaction between talker variability and bimodal hearing for any performance measure adopted in this study. Correlation analyses revealed that the bimodal performance and benefits in Mandarin tone, vowel, and syllable recognition could not be predicted by the hearing thresholds in the nonimplanted ear or by the demographic factors of the participants. Conclusions: Talker variability from trial to trial significantly degraded Mandarin tone and syllable recognition performance in both the CI alone and CI + HA conditions. While bimodal hearing did not reduce the talker variability effects on Mandarin tone and syllable recognition, generally better Mandarin tone and syllable recognition performance with shorter response time (an indicator of less listening effort) was observed when a contralateral HA was used in conjunction with the CI. On the other hand, vowel recognition was not significantly affected by either talker variability or bimodal hearing, because ceiling effects could not be counted out of the vowel recognition results. Copyright (C) 2016 Wolters Kluwer Health, Inc. All rights reserved.

from #Audiology via ola Kala on Inoreader http://ift.tt/1K9uioP
via IFTTT

Individual lipid encapsulated microbubble radial oscillations: Effects of fluid viscosity

Ultrasound-stimulated microbubble dynamics have been shown to be dependent on intrinsic bubble properties, including size and shell characteristics. The effect of the surrounding environment on microbubble response, however, has been less investigated. In particular, microbubble optimization studies are generally conducted in water/saline, characterized by a 1 cP viscosity, for application in the vasculature (i.e., 4 cP). In this study, ultra-high speed microscopy was employed to investigate fluid viscosityeffects on phospholipid encapsulated microbubble oscillations at 1 MHz, using a single, eight-cycle pulse at peak negative pressures of 100 and 250 kPa. Microbubble oscillations were shown to be affected by fluid viscosity in a size- and pressure-dependent manner. In general, the oscillation amplitudes exhibited by microbubbles between 3 and 6 μm in 1 cP fluid were larger than in 4 cP fluid, reaching a maximum of 1.7-fold at 100 kPa for microbubbles 3.8 μm in diameter and 1.35-fold at 250 kPa for microbubbles 4.8 μm in diameter. Simulation results were in broad agreement at 250 kPa, however generally underestimated the effect of fluid viscosity at 100 kPa. This is the first experimental demonstration documenting the effects of surrounding fluid viscosity on microbubble oscillations, resulting in behavior not entirely predicted by current microbubble models.



from #Audiology via xlomafota13 on Inoreader http://ift.tt/1RGkitF
via IFTTT

Characterization and reduction of flow separation in jet pumps for laminar oscillatory flows

A computational fluid dynamics model is used to predict the oscillatory flow through tapered cylindrical tube sections (jet pumps). The asymmetric shape of jet pumps results in a time-averaged pressure drop that can be used to suppress Gedeon streaming in closed-loop thermoacoustic devices. However, previous work has shown that flow separation in the diverging flow direction counteracts the time-averaged pressure drop. In this work, the characteristics of flow separation in jet pumps are identified and coupled with the observed jet pump performance. Furthermore, it is shown that the onset of flow separation can be shifted to larger displacement amplitudes by designs that have a smoother transition between the small opening and the tapered surface of the jet pump. These design alterations also reduce the duration of separated flow, resulting in more effective and robust jet pumps. To make the proposed jet pump designs more compact without reducing their performance, the minimum big opening radius that can be implemented before the local minor losses have an influence on the jet pump performance is investigated. To validate the numerical results, they are compared with experimental results for one of the proposed jet pump designs.



from #Audiology via xlomafota13 on Inoreader http://ift.tt/1ZghK61
via IFTTT

An examination of the different ways that non-native phones may be perceptually assimilated as uncategorized

This study examined three ways that perception of non-native phones may be uncategorized relative to native (L1) categories: focalized (predominantly similar to a single L1 category), clustered (similar to > 2 L1 categories), and dispersed (not similar to any L1 categories). In an online study, Egyptian Arabic speakers residing in Egypt categorized and rated all Australian English vowels. Evidence was found to support focalized, clustered, and dispersed uncategorized assimilations. Second-language (L2) category formation for uncategorized assimilations is predicted to depend upon the degree of perceptual overlap between the sets of L1 categories listeners use in assimilating each phone within an L2 contrast.



from #Audiology via xlomafota13 on Inoreader http://ift.tt/1K93i92
via IFTTT

An examination of the different ways that non-native phones may be perceptually assimilated as uncategorized

This study examined three ways that perception of non-native phones may be uncategorized relative to native (L1) categories: focalized (predominantly similar to a single L1 category), clustered (similar to > 2 L1 categories), and dispersed (not similar to any L1 categories). In an online study, Egyptian Arabic speakers residing in Egypt categorized and rated all Australian English vowels. Evidence was found to support focalized, clustered, and dispersed uncategorized assimilations. Second-language (L2) category formation for uncategorized assimilations is predicted to depend upon the degree of perceptual overlap between the sets of L1 categories listeners use in assimilating each phone within an L2 contrast.



from #Audiology via xlomafota13 on Inoreader http://ift.tt/1K93i92
via IFTTT

Decision-making and outcomes of hearing help-seekers: A self-determination theory perspective

10.3109/14992027.2015.1120893<br/>Jason Ridgway

from #Audiology via ola Kala on Inoreader http://ift.tt/1OKs3hl
via IFTTT

Initial classification of pediatric hearing impairment using behavioral measures of early prelingual auditory development

10.3109/14992027.2015.1120891<br/>Siyu Liang

from #Audiology via ola Kala on Inoreader http://ift.tt/1OKs3h7
via IFTTT

Decision-making and outcomes of hearing help-seekers: A self-determination theory perspective

10.3109/14992027.2015.1120893<br/>Jason Ridgway

from #Audiology via ola Kala on Inoreader http://ift.tt/1OKs3hl
via IFTTT

Initial classification of pediatric hearing impairment using behavioral measures of early prelingual auditory development

10.3109/14992027.2015.1120891<br/>Siyu Liang

from #Audiology via ola Kala on Inoreader http://ift.tt/1OKs3h7
via IFTTT

Decision-making and outcomes of hearing help-seekers: A self-determination theory perspective

10.3109/14992027.2015.1120893<br/>Jason Ridgway

from #Audiology via xlomafota13 on Inoreader http://ift.tt/1OKs3hl
via IFTTT

Initial classification of pediatric hearing impairment using behavioral measures of early prelingual auditory development

10.3109/14992027.2015.1120891<br/>Siyu Liang

from #Audiology via xlomafota13 on Inoreader http://ift.tt/1OKs3h7
via IFTTT

Decision-making and outcomes of hearing help-seekers: A self-determination theory perspective

10.3109/14992027.2015.1120893<br/>Jason Ridgway

from #Audiology via ola Kala on Inoreader http://ift.tt/1Sdchh2
via IFTTT

Initial classification of pediatric hearing impairment using behavioral measures of early prelingual auditory development

10.3109/14992027.2015.1120891<br/>Siyu Liang

from #Audiology via ola Kala on Inoreader http://ift.tt/1ZWi8ca
via IFTTT

Decision-making and outcomes of hearing help-seekers: A self-determination theory perspective

10.3109/14992027.2015.1120893<br/>Jason Ridgway

from #Audiology via ola Kala on Inoreader http://ift.tt/1Sdchh2
via IFTTT

Initial classification of pediatric hearing impairment using behavioral measures of early prelingual auditory development

10.3109/14992027.2015.1120891<br/>Siyu Liang

from #Audiology via ola Kala on Inoreader http://ift.tt/1ZWi8ca
via IFTTT

Review on clinical update of essential tremor.

Review on clinical update of essential tremor.

Neurol Sci. 2016 Jan 9;

Authors: Chunling W, Zheng X

Abstract
Essential tremor (ET) is considered a benign disease without any pathological changes. Nevertheless, this point of view has recently been challenged. In recent years, studies have shown that ET occurs with other non-motor symptoms, such as cognitive deficits, depression, anxiety, balance disorder, hearing impairment, olfactory dysfunction and sleep problems. Advancements in neuroimaging have revealed widespread alterations in the brain, and cerebellar involvement was the most consistent finding. In addition, studies have also shown that ET patients might experience poor quality of life, reflecting motor or non-motor symptoms. Both pharmacotherapy and non-pharmacotherapy have recently been suggested for the treatment of ET. This review briefly describes the current information on ET, including the non-movement symptoms, neuroimaging findings, the impact on daily life and ET therapy.

PMID: 26749268 [PubMed - as supplied by publisher]



from #Audiology via ola Kala on Inoreader http://ift.tt/1RwqINI
via IFTTT

Review on clinical update of essential tremor.

Review on clinical update of essential tremor.

Neurol Sci. 2016 Jan 9;

Authors: Chunling W, Zheng X

Abstract
Essential tremor (ET) is considered a benign disease without any pathological changes. Nevertheless, this point of view has recently been challenged. In recent years, studies have shown that ET occurs with other non-motor symptoms, such as cognitive deficits, depression, anxiety, balance disorder, hearing impairment, olfactory dysfunction and sleep problems. Advancements in neuroimaging have revealed widespread alterations in the brain, and cerebellar involvement was the most consistent finding. In addition, studies have also shown that ET patients might experience poor quality of life, reflecting motor or non-motor symptoms. Both pharmacotherapy and non-pharmacotherapy have recently been suggested for the treatment of ET. This review briefly describes the current information on ET, including the non-movement symptoms, neuroimaging findings, the impact on daily life and ET therapy.

PMID: 26749268 [PubMed - as supplied by publisher]



from #Audiology via ola Kala on Inoreader http://ift.tt/1RwqINI
via IFTTT