Τετάρτη 22 Δεκεμβρίου 2021

The Nonrecurrent Laryngeal Nerve Without Abnormal Subclavian Artery: Report of Two Cases and Review of the Literature

xlomafota13 shared this article with you from Inoreader

pubmed-meta-image.png

Ear Nose Throat J. 2021 Dec 22:1455613211056547. doi: 10.1177/01455613211056547. Online ahead of print.

ABSTRACT

As a variant of recurrent inferior laryngeal nerve (RILN), the nonrecurrent inferior laryngeal nerve (NRILN) is closely related to the occurrence of abnormal subclavian artery (ASA). The nonrecurrent inferior laryngeal nerve has been found in patients without arterial abnormalities, which is seen in the coexistence of NRILN and RILN, but it is easily confused with sympathetic-inferior laryngeal anastomosis branch (SILAB). We encountered 2 right NRILN patients without ASA during thyroid surgery. This article summarizes the characteristics of these cases and proposes methods to distinguish the coexistence of NRILN and RILN from SILAB. So far, 11 articles have reported 16 cases of NRILN without arterial abnormalities. In patients without artery abnormality, the vagus nerve could send out a descending branch NRILN at the bifurcation of the carotid artery and enter the larynx after anastomosis with RILN. Adequate dissection of the carotid sheath may avoid confusion with SILAB, and neural monitoring is also expected to provide a reference for the identification.

PMID:34935547 | DOI:10.1177/01455613211056547

View on the web

Τρίτη 21 Δεκεμβρίου 2021

Paracrine mechanisms of endothelial progenitor cells in vascular repair

xlomafota13 shared this article with you from Inoreader
Via histochem

pubmed-meta-image.png

Acta Histochem. 2021 Dec 17;124(1):151833. doi: 10.1016/j.acthis.2021.151833. Online ahead of print.

ABSTRACT

Endothelial progenitor cells (EPCs) play an important role in repairing damaged blood vessels and promoting neovascularization. However, the specific mechanism of EPCs promoting vascular repair is still unclear. Currently, there are two different views on the repair of damaged vessels by EPCs, one is that EPCs can directly differentiate into endothelial cells (ECs) a nd integrate into injured vessels, the other is that EPCs act on cells and blood vessels by releasing paracrine substances. But more evidence now supports the latter. Therefore, the paracrine mechanisms of EPCs are worth further study. This review describes the substances secreted by EPCs, some applications based on paracrine effects of EPCs, and the studies of paracrine mechanisms in cardiovascular diseases--all of these are to support the view that EPCs repair blood vessels through paracrine effects rather than integrating directly into damaged vessels.

PMID:34929523 | DOI:10.1016/j.acthis.2021.151833

View on the web

Reconstruction of midline abdominal defects with a deep inferior epigastric artery keystone-type perforator flap

xlomafota13 shared this article with you from Inoreader

J Plast Reconstr Aesthet Surg. 2021 Dec 7:S1748-6815(21)00650-1. doi: 10.1016/j.bjps.2021.11.103. Online ahead of print.

NO ABSTRACT

PMID:34930700 | DOI:10.1016/j.bjps.2021.11.103

View on the web

Cerebrospinal Fluid Leak Detection with a Carbon Nanotube-Based Field-Effect Transistor Biosensing Platform

xlomafota13 shared this article with you from Inoreader

ACS Appl Mater Interfaces. 2021 Dec 21. doi: 10.1021/acsami.1c19120. Online ahead of print.

ABSTRACT

Cerebrospinal fluid (CSF) leakage may lead to life-threatening complications if not detected promptly. However, gel electrophoresis, the gold-standard test for confirming CSF leakage by detecting beta2-transferrin (β2-Tf), requires 3-6 h and is labor-intensive. We developed a new β2-Tf detection platform for rapid identification of CSF leakage. The three-step design, which includes two steps of affinity chromatography and a rapid sensing step using a semiconductor-enriched single-walled carbon nanotube field-effect transistor (FET) sensor, circumvented the lack of selectivity that antitransferrin antibody exhibits for transferrin isoforms and markedly shortened the detection time. Furthermore, three different sensing configurations for the FET sensor were investigated for obtaining the optimal β2-Tf sensing results. Finally, body fluid (CSF and serum) tests employing our three-step strategy demonstrated high sensitivity, suggesting its potential to be used as a rapid diagnostic tool for CSF leakage.

PMID:34932323 | DOI:10.1021/acsami.1c19120

View on the web

Δευτέρα 20 Δεκεμβρίου 2021

Oligometastatic adenoid cystic carcinoma: Correlating tumor burden and time to treatment with outcomes

xlomafota13 shared this article with you from Inoreader

Abstract

Background

There is limited information on the management and outcomes of oligometastases (OM) in adenoid cystic carcinoma (ACC).

Methods

Retrospective study of 42 patients with metastatic ACC of the head and neck. Imaging studies were analyzed to identify patients with OM (1–5 lesions) at any point during follow-up.

Results

There was radiographic evidence of OM in 33/42 (79%) patients. Eighteen patients had OM when treated for metastases, with median overall survival (OS) of 36.0 versus 9.2 years for patients with polymetastases (6+ lesions, HR 0.38, 95%CI 0.14–0.89). Earlier locally ablative treatment, but not systemic treatment, of patients with OM predicted improved survival 3 years after metastasis (HR 0.15, 95%CI 0.02–0.63) and postponed systemic treatment by 80 more months (HR 0.22, 95%CI 0.07–0.71).

Conclusions

There is a considerable population of ACC patients with detectable oligometastases, and early locally ablative treatment of oligometastases may be associated with improved outcomes.

View on the web

Assessment of deep inferior epigastric perforator flap perfusion with near-infrared fluorescence: A pilot study and description of a standardized working protocol

xlomafota13 shared this article with you from Inoreader

J Plast Reconstr Aesthet Surg. 2021 Nov 16:S1748-6815(21)00590-8. doi: 10.1016/j.bjps.2021.11.043. Online ahead of print.

ABSTRACT

Fat necrosis (FN) is a common complication after autologous breast reconstruction (ABR) using a free flap, which can influence reconstruction outcome and patient satisfaction. Intraoperative near-infrared fluorescence imaging using indocyanine green (ICG) permits the visualization of flap perfusion. The aim of this study was to assess the effect of near-infrared fluorescence on FN incidence in patients undergoing an ABR with a deep inferior epigastric perforator flap (DIEP) and to propose a standard working protocol for this technique. In this prospective study, patients undergoing one-sided ABR with a DIEP were included. The standard DIEP procedure was complemented with near-infrared fluorescence imaging using the fluorescent tracer ICG to evaluate flap perfusion. This cohort was compared to a retrospectiv e cohort of DIEP procedures without near-infrared fluorescence imaging. Patients and surgery characteristics, as well as postoperative complications, were registered and compared. In both cohorts, 24 patients were included. No significant differences were present between patients and surgery characteristics, including no difference in duration of surgery. In the prospective and retrospective group, the incidence of FN was 4.2% and 33%, respectively (p-value = 0.023). Moreover, microsurgeons were positive about using near-infrared fluorescence as it either provided additional information about perfusion or confirmed the clinical assessment. Our pilot study showed a significant decrease of FN in patients undergoing an ABR with a DIEP when near-infrared fluorescence imaging was used to assess flap perfusion. This study provides a standardized working protocol for near-infrared fluorescence imaging. In the future, large multicenter studies should focus on the quantification of near-infr ared fluorescence imaging.

PMID:34924327 | DOI:10.1016/j.bjps.2021.11.043

View on the web

Effects of background noise on auditory response characteristics of primary auditory cortex neurons in awake mice

xlomafota13 shared this article with you from Inoreader

Nan Fang Yi Ke Da Xue Xue Bao. 2021 Nov 20;41(11):1672-1679. doi: 10.12122/j.issn.1673-4254.2021.11.11.

ABSTRACT

OBJECTIVE: To study the effects of different continuous background noises on auditory response characteristics of primary auditory cortex (A1) neurons in awake mice.

METHODS: We performed in vivo cell-attached recordings in layer 4 neurons of the A1 of awake mice to investigate how continuous background noises of different levels affected the intensity tuning, frequency tuning and time characteristics of individual A1 neurons. According to the intensity tuning characteristics and types of stimulation, 44 neurons were devided into 4 groups: monotonic-intensity group (20 monotonic neurons), nonmonotonic-intensity group (6 nonmonotonic neurons), monotonic-frequency group (25 monotonic neurons) and monotonic-latency group (15 monotonic neurons).

RESULTS: The A1 neurons only had transient spike response within 10 to 40 ms af ter the onset of continuous wild-band noise stimulation. The noise intensity had no significant effects on the background firing rates of the A1 neurons (P>0.05). The increase of background noise resulted in a significant linear elevation of the intensity threshold of monotonic and nonmonotonic neurons for tone-evoked response (R2>0.90, P < 0.05). No significant difference was observed in the slopes of threshold changes between monotonic and nonmonotonic neurons (P>0.05). The best intensity of nonmonotonic neurons increased along with the intensity of the background noise, and the variation of the best intensity was positively correlated with the change of the threshold of the same neuron (r=0.944, P < 0.001). The frequency response bandwidth and the firing rate of the A1 neurons decreased as the noise intensity increased (P < 0.001), but the best frequency almost remained unchanged (P < 0.001). The increase of background noise intensity resulted in an increased first spike latency of the neurons to the same tone stimulus (P < 0.05) without affecting the time accuracy of the first action potential (P>0.05).

CONCLUSION: The acoustic response threshold of the A1 neurons increases linearly with the increase of background noise intensity. An increased background noise leads to compressed frequency band-width, a decreased firing rate and a prolonged spike latency, but the frequency selectivity and the time accuracy of auditory response to the same noise remain stable.

PMID:34916193 | DOI:10.12122/j.issn.1673-4254.2021.11.11

View on the web