Πέμπτη 31 Δεκεμβρίου 2015

Simultaneous Assessment of Speech Identification and Spatial Discrimination: A Potential Testing Approach for Bilateral Cochlear Implant Users?

With increasing numbers of children and adults receiving bilateral cochlear implants, there is an urgent need for assessment tools that enable testing of binaural hearing abilities. Current test batteries are either limited in scope or are of an impractical duration for routine testing. Here, we report a behavioral test that enables combined testing of speech identification and spatial discrimination in noise. In this task, multitalker babble was presented from all speakers, and pairs of speech tokens were sequentially presented from two adjacent speakers. Listeners were required to identify both words from a closed set of four possibilities and to determine whether the second token was presented to the left or right of the first. In Experiment 1, normal-hearing adult listeners were tested at 15° intervals throughout the frontal hemifield. Listeners showed highest spatial discrimination performance in and around the frontal midline, with a decline at more eccentric locations. In contrast, speech identification abilities were least accurate near the midline and showed an improvement in performance at more lateral locations. In Experiment 2, normal-hearing listeners were assessed using a restricted range of speaker locations designed to match those found in clinical testing environments. Here, speakers were separated by 15° around the midline and 30° at more lateral locations. This resulted in a similar pattern of behavioral results as in Experiment 1. We conclude, this test offers the potential to assess both spatial discrimination and the ability to use spatial information for unmasking in clinical populations.



from #Audiology via xlomafota13 on Inoreader http://ift.tt/1UjepkZ
via IFTTT

Advancing Binaural Cochlear Implant Technology

This special issue contains a collection of 13 papers highlighting the collaborative research and engineering project entitled Advancing Binaural Cochlear Implant Technology—ABCIT—as well as research spin-offs from the project. In this introductory editorial, a brief history of the project is provided, alongside an overview of the studies.



from #Audiology via xlomafota13 on Inoreader http://ift.tt/1YSyYvg
via IFTTT

Reducing Current Spread by Use of a Novel Pulse Shape for Electrical Stimulation of the Auditory Nerve

Improving the electrode-neuron interface to reduce current spread between individual electrodes has been identified as one of the main objectives in the search for future improvements in cochlear-implant performance. Here, we address this problem by presenting a novel stimulation strategy that takes account of the biophysical properties of the auditory neurons (spiral ganglion neurons, SGNs) stimulated in electrical hearing. This new strategy employs a ramped pulse shape, where the maximum amplitude is achieved through a linear slope in the injected current. We present the theoretical framework that supports this new strategy and that suggests it will improve the modulation of SGNs’ activity by exploiting their sensitivity to the rising slope of current pulses. The theoretical consequence of this sensitivity to the slope is a reduction in the spread of excitation within the cochlea and, consequently, an increase in the neural dynamic range. To explore the impact of the novel stimulation method on neural activity, we performed in vitro recordings of SGNs in culture. We show that the stimulus efficacy required to evoke action potentials in SGNs falls as the stimulus slope decreases. This work lays the foundation for a novel, and more biomimetic, stimulation strategy with considerable potential for implementation in cochlear-implant technology.



from #Audiology via xlomafota13 on Inoreader http://ift.tt/1YSz06x
via IFTTT

Sparse Nonnegative Matrix Factorization Strategy for Cochlear Implants

Current cochlear implant (CI) strategies carry speech information via the waveform envelope in frequency subbands. CIs require efficient speech processing to maximize information transfer to the brain, especially in background noise, where the speech envelope is not robust to noise interference. In such conditions, the envelope, after decomposition into frequency bands, may be enhanced by sparse transformations, such as nonnegative matrix factorization (NMF). Here, a novel CI processing algorithm is described, which works by applying NMF to the envelope matrix (envelopogram) of 22 frequency channels in order to improve performance in noisy environments. It is evaluated for speech in eight-talker babble noise. The critical sparsity constraint parameter was first tuned using objective measures and then evaluated with subjective speech perception experiments for both normal hearing and CI subjects. Results from vocoder simulations with 10 normal hearing subjects showed that the algorithm significantly enhances speech intelligibility with the selected sparsity constraints. Results from eight CI subjects showed no significant overall improvement compared with the standard advanced combination encoder algorithm, but a trend toward improvement of word identification of about 10 percentage points at +15 dB signal-to-noise ratio (SNR) was observed in the eight CI subjects. Additionally, a considerable reduction of the spread of speech perception performance from 40% to 93% for advanced combination encoder to 80% to 100% for the suggested NMF coding strategy was observed.



from #Audiology via xlomafota13 on Inoreader http://ift.tt/1Ujeoxs
via IFTTT

A Binaural Steering Beamformer System for Enhancing a Moving Speech Source

In many daily life communication situations, several sound sources are simultaneously active. While normal-hearing listeners can easily distinguish the target sound source from interfering sound sources—as long as target and interferers are spatially or spectrally separated—and concentrate on the target, hearing-impaired listeners and cochlear implant users have difficulties in making such a distinction. In this article, we propose a binaural approach composed of a spatial filter controlled by a direction-of-arrival estimator to track and enhance a moving target sound. This approach was implemented on a real-time signal processing platform enabling experiments with test subjects in situ. To evaluate the proposed method, a data set of sound signals with a single moving sound source in an anechoic diffuse noise environment was generated using virtual acoustics. The proposed steering method was compared with a fixed (nonsteering) method that enhances sound from the frontal direction in an objective evaluation and subjective experiments using this database. In both cases, the obtained results indicated a significant improvement in speech intelligibility and quality compared with the unprocessed signal. Furthermore, the proposed method outperformed the nonsteering method.



from #Audiology via xlomafota13 on Inoreader http://ift.tt/1YSyXHO
via IFTTT

Simultaneous Assessment of Speech Identification and Spatial Discrimination: A Potential Testing Approach for Bilateral Cochlear Implant Users?

With increasing numbers of children and adults receiving bilateral cochlear implants, there is an urgent need for assessment tools that enable testing of binaural hearing abilities. Current test batteries are either limited in scope or are of an impractical duration for routine testing. Here, we report a behavioral test that enables combined testing of speech identification and spatial discrimination in noise. In this task, multitalker babble was presented from all speakers, and pairs of speech tokens were sequentially presented from two adjacent speakers. Listeners were required to identify both words from a closed set of four possibilities and to determine whether the second token was presented to the left or right of the first. In Experiment 1, normal-hearing adult listeners were tested at 15° intervals throughout the frontal hemifield. Listeners showed highest spatial discrimination performance in and around the frontal midline, with a decline at more eccentric locations. In contrast, speech identification abilities were least accurate near the midline and showed an improvement in performance at more lateral locations. In Experiment 2, normal-hearing listeners were assessed using a restricted range of speaker locations designed to match those found in clinical testing environments. Here, speakers were separated by 15° around the midline and 30° at more lateral locations. This resulted in a similar pattern of behavioral results as in Experiment 1. We conclude, this test offers the potential to assess both spatial discrimination and the ability to use spatial information for unmasking in clinical populations.



from #Audiology via ola Kala on Inoreader http://ift.tt/1UjepkZ
via IFTTT

Sensitivity to Envelope Interaural Time Differences at High Modulation Rates

Sensitivity to interaural time differences (ITDs) conveyed in the temporal fine structure of low-frequency tones and the modulated envelopes of high-frequency sounds are considered comparable, particularly for envelopes shaped to transmit similar fidelity of temporal information normally present for low-frequency sounds. Nevertheless, discrimination performance for envelope modulation rates above a few hundred Hertz is reported to be poor—to the point of discrimination thresholds being unattainable—compared with the much higher (>1,000 Hz) limit for low-frequency ITD sensitivity, suggesting the presence of a low-pass filter in the envelope domain. Further, performance for identical modulation rates appears to decline with increasing carrier frequency, supporting the view that the low-pass characteristics observed for envelope ITD processing is carrier-frequency dependent. Here, we assessed listeners’ sensitivity to ITDs conveyed in pure tones and in the modulated envelopes of high-frequency tones. ITD discrimination for the modulated high-frequency tones was measured as a function of both modulation rate and carrier frequency. Some well-trained listeners appear able to discriminate ITDs extremely well, even at modulation rates well beyond 500 Hz, for 4-kHz carriers. For one listener, thresholds were even obtained for a modulation rate of 800 Hz. The highest modulation rate for which thresholds could be obtained declined with increasing carrier frequency for all listeners. At 10 kHz, the highest modulation rate at which thresholds could be obtained was 600 Hz. The upper limit of sensitivity to ITDs conveyed in the envelope of high-frequency modulated sounds appears to be higher than previously considered.



from #Audiology via xlomafota13 on Inoreader http://ift.tt/1UjemWr
via IFTTT