Objectives: Cochlear implant (CI) sound processing strategies are usually evaluated in clinical studies involving experienced implant recipients. Metrics which estimate the capacity to perceive speech for a given set of audio and processing conditions provide an alternative means to assess the effectiveness of processing strategies. The aim of this research was to assess the ability of the output signal to noise ratio (OSNR) to accurately predict speech perception. It was hypothesized that compared with the other metrics evaluated in this study (1) OSNR would have equivalent or better accuracy and (2) OSNR would be the most accurate in the presence of variable levels of speech presentation. Design: For the first time, the accuracy of OSNR as a metric which predicts speech intelligibility was compared, in a retrospective study, with that of the input signal to noise ratio (ISNR) and the short-term objective intelligibility (STOI) metric. Because STOI measured audio quality at the input to a CI sound processor, a vocoder was applied to the sound processor output and STOI was also calculated for the reconstructed audio signal (vocoder short-term objective intelligibility [VSTOI] metric). The figures of merit calculated for each metric were Pearson correlation of the metric and a psychometric function fitted to sentence scores at each predictor value (Pearson sigmoidal correlation [PSIG]), epsilon insensitive root mean square error (RMSE*) of the psychometric function and the sentence scores, and the statistical deviance of the fitted curve to the sentence scores (D). Sentence scores were taken from three existing data sets of Australian Sentence Tests in Noise results. The AuSTIN tests were conducted with experienced users of the Nucleus CI system. The score for each sentence was the proportion of morphemes the participant correctly repeated. In data set 1, all sentences were presented at 65 dB sound pressure level (SPL) in the presence of four-talker Babble noise. Each block of sentences used an adaptive procedure, with the speech presented at a fixed level and the ISNR varied. In data set 2, sentences were presented at 65 dB SPL in the presence of stationary speech weighted noise, street-side city noise, and cocktail party noise. An adaptive ISNR procedure was used. In data set 3, sentences were presented at levels ranging from 55 to 89 dB SPL with two automatic gain control configurations and two fixed ISNRs. Results: For data set 1, the ISNR and OSNR were equally most accurate. STOI was significantly different for deviance (p = 0.045) and RMSE* (p
from #Audiology via ola Kala on Inoreader http://ift.tt/2CFPFk4
via IFTTT
OtoRhinoLaryngology by Sfakianakis G.Alexandros Sfakianakis G.Alexandros,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,tel : 00302841026182,00306932607174
Παρασκευή 23 Φεβρουαρίου 2018
An Evaluation of Output Signal to Noise Ratio as a Predictor of Cochlear Implant Speech Intelligibility
Ετικέτες
#Medicine by Alexandros G.Sfakianakis,
Anapafseos 5 Agios Nikolaos,
Crete 72100,
Greece,
tel :00302841026182 & 00306932607174
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου