Πέμπτη 20 Ιανουαρίου 2022

Physical activity ameliorates the function of organs via adipose tissue in metabolic diseases

xlomafota13 shared this article with you from Inoreader
Via histochem

pubmed-meta-image.png

Acta Histochem. 2022 Jan 16;124(2):151844. doi: 10.1016/j.acthis.2022.151844. Online ahead of print.

ABSTRACT

Adipose tissue is a dynamic organ in the endocrine system that can connect organs by secreting molecules and bioactive. Hence, adipose tissue really plays a pivotal role in regulating metabolism, inflammation, energy homeostasis, and thermogenesis. Disruption of hub bioactive molecules secretion such as adipokines leads to dysregulate metabolic communication between a dipose tissue and other organs in non-communicable disorders. Moreover, a sedentary lifestyle may be a risk factor for adipose tissue function. Physical inactivity leads to fat tissue accumulation and promotes obesity, Type 2 diabetes, cardiovascular disease, neurodegenerative disease, fatty liver, osteoporosis, and inflammatory bowel disease. On the other hand, physical activity may ameliorate and protect the body against metabolic disorders, triggering thermogenesis, metabolism, mitochondrial biogenesis, β-oxidation, and glucose uptake. Furthermore, physical activity provides an inter-organ association and cross-talk between different tissues by improving adipose tissue function, reprogramming gene expression, modulating molecules and bioactive factors. Also, physical activity decreases chronic inflammation, oxidative stress and improves metabolic features in adipose tissue. The current review focuses on the beneficial effect of physical activity on the cardiovascular, locomotor, digestive, and nervous systems. In addition, we visualize protein-protein interactions networks between hub proteins involved in dysregulating metabolic induced by adipose tissue.

PMID:35045377 | DOI:10.1016/j.acthis.2022.151844

View on the web

Chaos Behavior Analysis of Alaryngeal Voices Including Esophageal (SE) and Tracheoesophageal (TE) Voices

xlomafota13 shared this article with you from Inoreader

KargerLogo_article.png

ABSTRACT Hypothesis/Objectives This study's objective was to develop a method to the evaluate the chaotic characteristic of alaryngeal speech. The proposed method will be capable of distinguishing between normal and alaryngeal voices, including esophageal (SE) and tracheoesophageal (TE) voices. It has been previously shown that alaryngeal voices exhibit chaotic characteristics due to the aperiodicity of their signals. The proposed method will be applied for future use to quantify both chaos behavior and the difference between SE and TE voices. Study Design A total of 74 voice recordings including 34 normal and 40 alaryngeal (26 esophageal (SE) and 14 tracheoesophageal (TE)) were used in the study. Voice samples were analyzed to distinguish alaryngeal voices from normal voices and investigate different chaotic characteristics of SE and TE speech. Methods A chaotic distribution detection-based method was used to investigate the chaos behavior of alaryngeal voices. This chaos behavior was used to detect the difference between SE and TE voice types. Quantification of the chaos behavior (CB) parameter was performed. Statistical analyses were used to compare the results of the CB analysis for both the SE and TE voices. Results Statistical analysis revealed that CB effectively differentiated between all normal and alaryngeal voice types (P
View on the web

Challenges in Interpreting Thyroid Stimulating Hormone Results in the Diagnosis of Thyroid Dysfunction

xlomafota13 shared this article with you from Inoreader

jtr.banner.jpg

The pituitary hormone, thyrotropin (TSH), is regarded as the primary biomarker for evaluating thyroid function and is useful in guiding treatment with levothyroxine for patients with hypothyroidism. The amplified response of TSH to slight changes in thyroid hormone levels provides a large and easily measured signal in the routine care setting. Laboratories provide reference ranges with upper and lower cutoffs for TSH to define normal thyroid function. The upper limit of the range, used to diagnose subclinical (mild) hypothyroidism, is itself a matter for debate, with authoritative guidelines recommending treatment to within the lower half of the range. Concomitant diseases, medications, supplements, age, gender, ethnicity, iodine status, time of day, time of year, autoantibodies, heterophilic ant ibodies, smoking, and other factors influence the level of TSH, or the performance of current TSH assays. The long-term prognostic implications of small deviations of TSH from the reference range are unclear. Correction of TSH to within the reference range does not always bring thyroid and other biomarkers into range and will not always resolve the patient's symptoms. Overt hypothyroidism requires intervention with levothyroxine. It remains important that physicians managing a patient with symptoms suggestive of thyroid disease consider all of the patient's relevant disease, lifestyle, and other factors before intervening on the basis of a marginally raised TSH level alone. Finally, these limitations of TSH testing mitigate against screening the population for the undoubtedly substantial prevalence of undiagnosed thyroid disease, until appropriately designed randomised trials have quantified the benefits and harms from this approach.
View on the web

Increasing the reliability of real-time electrocochleography during cochlear implantation: a standardized guideline

xlomafota13 shared this article with you from Inoreader

Eur Arch Otorhinolaryngol. 2022 Jan 20. doi: 10.1007/s00405-021-07204-7. Online ahead of print.

ABSTRACT

PURPOSE: Electrocochleography (ECochG) measures electrical potentials generated by the inner ear in response to acoustic stimulation. Real-time (rt) recordings are increasingly used during cochlear implant (CI) surgeries to monitor the inner ear function. However, the performance of rt-ECochG is a delicate measurement procedure involving several pitfalls, which lead to inaccurate or invalid signal recordings in up to 20%. In order to use the technique routinely in CI candidates, an improvement in measurement reliability must be achieved.

METHODS: In our prospective study, we systematically investigated potential pitfalls and error sources during rt-ECochG recordings. We performed experiments (i) on a head and torso simulator, (ii) on a whole-head cadaver specimen, (iii) as well as in vivo during rt-ECochG recordings in CI reci pients. After analyzing experiments i-iii, a standardized measurement procedure was developed. We followed this guideline in 10 CI recipients to test the measurement reliability.

RESULTS: Besides improper installation, surgical and patient-specific factors influenced the measured signal. In particular, the unattenuated presentation of the acoustic stimulus was of importance. We summarized our findings in a standardized guideline. Following this guideline, we measured successful intraoperative ECochG recordings in 9/10 patients.

CONCLUSIONS: Our error analysis improved the understanding of successful rt-ECochG measurements. When following our proposed guideline, we achieved more reliable intraoperative ECochG recordings.

PMID:35048175 | DOI:10.1007/s00405-021-07204-7

View on the web