Objective: To assess the hearing preservation outcomes in a large group of adult cochlear implant recipients implanted with a thin straight electrode array using atraumatic surgical techniques. Factors affecting hearing preservation will be investigated. Study Design: Prospective cohort study undertaken at the Royal Victorian Eye and Ear Hospital in Melbourne, Australia from December 2010 to May 2015. Setting: Tertiary academic hospital. Patients: One hundred thirty-nine adults undergoing cochlear implantation (CI). Main Outcome Measure: Primary outcome measure of interest was pre and postoperative pure-tone audiometry. Results: Median low-frequency hearing change for the whole group of 139 recipients was -22.5 dB at the 3 months postop point. Eighty-six participants had functional preoperative low-frequency hearing (