Hypothesis: The use of larger-diameter pistons in stapedotomy leads to better hearing outcomes compared with the use of smaller-diameter pistons. There is an interaction between stapes piston diameter and fenestration diameter. Background: Otosclerosis can be treated surgically by removing part of the stapes and bypassing the stapes footplate with a prosthesis. Available piston shaft diameters range between 0.3 and 0.8 mm. There has been a tendency toward the use of smaller-diameter pistons, because of a suspected decreased risk of cochlear trauma and subsequent sensorineural hearing loss (SNHL) with smaller pistons. However, mathematical models, temporal bone studies, and clinical studies suggest that the use of larger-diameter pistons is associated with better hearing outcomes. Methods: Three fresh-frozen, non-pathologic temporal bones were harvested from human cadaveric donors. Acoustic stimuli in the form of pure tones from 250 to 8000 Hz were generated at 110 dB sound pressure level. A total of 16 frequencies in a 1/3-octave series were used. Stapes and round window velocities in response to the acoustic stimuli were measured at multiple equally spaced points covering the stapes footplate and round window using a scanning laser Doppler interferometry system. Eight sets of measurements were performed in each temporal bone: 1) normal condition (mobile stapes), 2) stapes fixation and stapedotomy followed by insertion of 3) a 0.4-mm-diameter piston in a 0.5-mm-diameter fenestration, 4) a 0.4-mm-diameter piston in a 0.7-mm-diameter fenestration, 5) a 0.4-mm-diameter piston in a 0.9-mm-diameter fenestration, 6) a 0.6-mm-diameter piston in a 0.7-mm-diameter fenestration, 7) a 0.6-mm-diameter piston in a 0.9-mm-diameter fenestration, and 8) a 0.8-mm-diameter piston in a 0.9-mm-diameter fenestration. Results: At midrange frequencies, between 500 and 4000 Hz, round window velocities increased by 2 to 3 dB when using a 0.6-mm-diameter piston compared with a 0.4-mm-diameter piston. Using a 0.8-mm-diameter piston led to a further increase in round window velocities by 2 to 4 dB. Conclusion: Our results suggest a modest effect of piston diameter on hearing results following stapedotomy. Copyright (C) 2016 by Otology & Neurotology, Inc. Image copyright (C) 2010 Wolters Kluwer Health/Anatomical Chart Company
from #Audiology via xlomafota13 on Inoreader http://ift.tt/2cEXorR
via IFTTT
OtoRhinoLaryngology by Sfakianakis G.Alexandros Sfakianakis G.Alexandros,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,tel : 00302841026182,00306932607174
Τρίτη 20 Σεπτεμβρίου 2016
The Effect of Piston Diameter in Stapedotomy for Otosclerosis: A Temporal Bone Model.
Ετικέτες
#Medicine by Alexandros G.Sfakianakis,
Anapafseos 5 Agios Nikolaos,
Crete 72100,
Greece,
tel :00302841026182 & 00306932607174
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου