Τετάρτη 14 Σεπτεμβρίου 2016

Comparing Measures of Voice Quality From Sustained Phonation and Continuous Speech

Purpose
The question of what type of utterance—a sustained vowel or continuous speech—is best for voice quality analysis has been extensively studied but with equivocal results. This study examines whether previously reported differences derive from the articulatory and prosodic factors occurring in continuous speech versus sustained phonation.
Method
Speakers with voice disorders sustained vowels and read sentences. Vowel samples were excerpted from the steadiest portion of each vowel in the sentences. In addition to sustained and excerpted vowels, a 3rd set of stimuli was created by shortening sustained vowel productions to match the duration of vowels excerpted from continuous speech. Acoustic measures were made on the stimuli, and listeners judged the severity of vocal quality deviation.
Results
Sustained vowels and those extracted from continuous speech contain essentially the same acoustic and perceptual information about vocal quality deviation.
Conclusions
Perceived and/or measured differences between continuous speech and sustained vowels derive largely from voice source variability across segmental and prosodic contexts and not from variations in vocal fold vibration in the quasisteady portion of the vowels. Approaches to voice quality assessment by using continuous speech samples average across utterances and may not adequately quantify the variability they are intended to assess.

from #Audiology via xlomafota13 on Inoreader http://ift.tt/2cs7KYI