Πέμπτη 25 Αυγούστου 2016

Neonate Auditory Brainstem Responses to CE-Chirp and CE-Chirp Octave Band Stimuli I Versus Click and Tone Burst Stimuli.

wk-health-logo.gif

Objectives: The purpose of the study was to generate normative auditory brainstem response (ABR) wave component peak latency and amplitude values for neonates with air- and bone-conducted CE-Chirps and air-conducted CE-Chirp octave band stimuli (i.e., 500, 1000, 2000, and 4000 Hz). A second objective was to compare neonate ABRs to CE-Chirp stimuli with ABR responses to traditional click and tone burst stimuli with the same stimulus parameters. Design: Participants were 168 healthy neonates. ABRs were obtained to air- and bone-conducted CE-Chirp and click stimuli and air-conducted CE-Chirp octave band and tone burst stimuli. The effects of stimulus level, rate, and polarity were examined with air-conducted CE-Chirps and clicks. The effect of stimulus level was also examined with bone-conducted CE-Chirps and clicks and air-conducted CE-Chirp octave band stimuli. Results: In general, ABR wave V amplitudes to air- and bone-conducted CE-Chirp stimuli were significantly larger (p

from #Audiology via xlomafota13 on Inoreader http://ift.tt/2bidL7b
via IFTTT

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου