Evaluation of a wireless audio streaming accessory to improve mobile telephone performance of cochlear implant users.

Evaluation of a wireless audio streaming accessory to improve mobile telephone performance of cochlear implant users.

Int J Audiol. 2016 Feb;55(2):75-82

Authors: Wolfe J, Morais Duke M, Schafer E, Cire G, Menapace C, O'Neill L

Abstract
OBJECTIVE: The objective of this study was to evaluate the potential improvement in word recognition in quiet and in noise obtained with use of a Bluetooth-compatible wireless hearing assistance technology (HAT) relative to the acoustic mobile telephone condition (e.g. the mobile telephone receiver held to the microphone of the sound processor).
DESIGN: A two-way repeated measures design was used to evaluate differences in telephone word recognition obtained in quiet and in competing noise in the acoustic mobile telephone condition compared to performance obtained with use of the CI sound processor and a telephone HAT.
STUDY SAMPLE: Sixteen adult users of Nucleus cochlear implants and the Nucleus 6 sound processor were included in this study.
RESULTS: Word recognition over the mobile telephone in quiet and in noise was significantly better with use of the wireless HAT compared to performance in the acoustic mobile telephone condition. Word recognition over the mobile telephone was better in quiet when compared to performance in noise.
CONCLUSIONS: The results of this study indicate that use of a wireless HAT improves word recognition over the mobile telephone in quiet and in noise relative to performance in the acoustic mobile telephone condition for a group of adult cochlear implant recipients.

PMID: 26681229 [PubMed - in process]



from #Audiology via ola Kala on Inoreader http://ift.tt/1YrPNry
via IFTTT

GeneReviews(®)

http:--http://ift.tt/1Fkw4zC

GeneReviews(®)

Book. 1993

Authors: Pagon RA, Adam MP, Ardinger HH, Wallace SE, Amemiya A, Bean LJH, Bird TD, Fong CT, Mefford HC, Smith RJH, Stephens K

Abstract
CLINICAL DESCRIPTION: Action myoclonus – renal failure (AMRF) syndrome typically comprises a continuum of two major (and ultimately fatal) manifestations: progressive myoclonic epilepsy (PME) and renal failure; however, in some instances, the kidneys are not involved. Neurologic manifestations can appear before, simultaneously, or after the renal manifestations. Disease manifestations are usually evident in the late teens or early twenties. In the rare instances in which renal manifestations precede neurologic findings, onset is usually in late childhood/early adolescence but can range to the fifth or sixth decade. Neurologic manifestations begin with tremor at rest (which is exacerbated by fine motor activities) and progress to involuntary, action-activated myoclonic jerks that involve bulbar, proximal, and distal limb muscles; involuntary spontaneous myoclonic jerks; and generalized clonic-tonic-clonic seizures. Sensorimotor peripheral neuropathy and sensorineural hearing loss can also be observed. Renal manifestations include proteinuria that can progress to nephrotic syndrome and end-stage renal disease.
DIAGNOSIS/TESTING: The diagnosis of AMRF syndrome is suspected in a previously healthy teenager or young adult with the characteristic neurologic and/or renal manifestations. The diagnosis is confirmed in individuals with biallelic (homozygous or compound heterozygous) loss-of-function pathogenic variants in SCARB2.
MANAGEMENT: Treatment of manifestations: Symptomatic pharmacologic and psychosocial support is the mainstay of care for the neurologic manifestations. Response to treatment is variable and may worsen over time, necessitating rehabilitative management. Renal insufficiency requires dialysis but response to treatment is poor, and renal transplantation is often necessary. Prevention of secondary complications: Standard measures for prevention of aspiration pneumonia and sudden unexpected death in epilepsy should be followed. Surveillance: Lifelong follow up should include regular monitoring of antiepileptic drug treatment and renal function (including urinary protein excretion, creatinine clearance, and estimated glomerular filtration rate) and periodic assessment of hearing and peripheral nerves. Agents/circumstances to avoid: Diphenylhydantoin, carbamazepine, oxcarbazepine, and possibly lamotrigine increase myoclonus and should be avoided in any individual with PME. Pregnancy management: Because some antiepileptic drugs can lead to an increased risk of malformations, growth retardation, or neurodevelopmental disabilities in exposed fetuses, standard measures for prevention of fetopathy should be followed.
GENETIC COUNSELING: AMRF syndrome is inherited in an autosomal recessive manner. At conception, each sib of an affected individual has a 25% chance of being affected, a 50% chance of being an asymptomatic carrier, and a 25% chance of being unaffected and not a carrier. Carrier testing for at-risk relatives and prenatal testing for pregnancies at increased risk require prior identification of the SCARB2 pathogenic variants in the family.


PMID: 26677510



from #Audiology via xlomafota13 on Inoreader http://ift.tt/1RvfurX
via IFTTT

Evaluation of a wireless audio streaming accessory to improve mobile telephone performance of cochlear implant users.

Evaluation of a wireless audio streaming accessory to improve mobile telephone performance of cochlear implant users.

Int J Audiol. 2016 Feb;55(2):75-82

Authors: Wolfe J, Morais Duke M, Schafer E, Cire G, Menapace C, O'Neill L

Abstract
OBJECTIVE: The objective of this study was to evaluate the potential improvement in word recognition in quiet and in noise obtained with use of a Bluetooth-compatible wireless hearing assistance technology (HAT) relative to the acoustic mobile telephone condition (e.g. the mobile telephone receiver held to the microphone of the sound processor).
DESIGN: A two-way repeated measures design was used to evaluate differences in telephone word recognition obtained in quiet and in competing noise in the acoustic mobile telephone condition compared to performance obtained with use of the CI sound processor and a telephone HAT.
STUDY SAMPLE: Sixteen adult users of Nucleus cochlear implants and the Nucleus 6 sound processor were included in this study.
RESULTS: Word recognition over the mobile telephone in quiet and in noise was significantly better with use of the wireless HAT compared to performance in the acoustic mobile telephone condition. Word recognition over the mobile telephone was better in quiet when compared to performance in noise.
CONCLUSIONS: The results of this study indicate that use of a wireless HAT improves word recognition over the mobile telephone in quiet and in noise relative to performance in the acoustic mobile telephone condition for a group of adult cochlear implant recipients.

PMID: 26681229 [PubMed - in process]



from #Audiology via ola Kala on Inoreader http://ift.tt/1YrPNry
via IFTTT

Functional-structural reorganisation of the neuronal network for auditory perception in subjects with unilateral hearing loss: Review of neuroimaging studies

Publication date: Available online 19 December 2015
Source:Hearing Research
Author(s): Peder O.Laugen Heggdal, Jonas Brännström, Hans Jørgen Aarstad, Flemming S. Vassbotn, Karsten Specht
ObjectiveThis paper aims to provide a review of studies using neuroimaging to measure functional-structural reorganisation of the neuronal network for auditory perception after unilateral hearing loss.DesignA literature search was performed in PubMed. Search criterions were peer reviewed original research papers in English completed by the 11th of March 2015.Study sampleTwelve studies were found to use neuroimaging in subjects with unilateral hearing loss. An additional five papers not identified by the literature search were provided by a reviewer. Thus, a total of 17 studies were included in the review.ResultsFour different neuroimaging methods were used in these studies: Functional magnetic resonance imaging (fMRI) (n = 11), diffusion tensor imaging (DTI) (n = 4), T1/T2 volumetric images (n = 2), magnetic resonance spectroscopy (MRS) (n = 1). One study utilized two imaging methods (fMRI and T1 volumetric images).ConclusionNeuroimaging techniques could provide valuable information regarding the effects of unilateral hearing loss on both auditory and non-auditory performance. fMRI-studies showing a bilateral BOLD-response in patients with unilateral hearing loss have not yet been followed by DTI studies confirming their microstructural correlates. In addition, the review shows that an auditory modality-specific deficit could affect multi-modal brain regions and their connections.



from #Audiology via ola Kala on Inoreader http://ift.tt/1ND0sL1
via IFTTT

Functional-structural reorganisation of the neuronal network for auditory perception in subjects with unilateral hearing loss: Review of neuroimaging studies

Publication date: Available online 19 December 2015
Source:Hearing Research
Author(s): Peder O.Laugen Heggdal, Jonas Brännström, Hans Jørgen Aarstad, Flemming S. Vassbotn, Karsten Specht
ObjectiveThis paper aims to provide a review of studies using neuroimaging to measure functional-structural reorganisation of the neuronal network for auditory perception after unilateral hearing loss.DesignA literature search was performed in PubMed. Search criterions were peer reviewed original research papers in English completed by the 11th of March 2015.Study sampleTwelve studies were found to use neuroimaging in subjects with unilateral hearing loss. An additional five papers not identified by the literature search were provided by a reviewer. Thus, a total of 17 studies were included in the review.ResultsFour different neuroimaging methods were used in these studies: Functional magnetic resonance imaging (fMRI) (n = 11), diffusion tensor imaging (DTI) (n = 4), T1/T2 volumetric images (n = 2), magnetic resonance spectroscopy (MRS) (n = 1). One study utilized two imaging methods (fMRI and T1 volumetric images).ConclusionNeuroimaging techniques could provide valuable information regarding the effects of unilateral hearing loss on both auditory and non-auditory performance. fMRI-studies showing a bilateral BOLD-response in patients with unilateral hearing loss have not yet been followed by DTI studies confirming their microstructural correlates. In addition, the review shows that an auditory modality-specific deficit could affect multi-modal brain regions and their connections.



from #Audiology via ola Kala on Inoreader http://ift.tt/1ND0sL1
via IFTTT

Longitudinal development of wideband reflectance tympanometry in normal and at-risk infants

Publication date: Available online 19 December 2015
Source:Hearing Research
Author(s): Lisa L. Hunter, Douglas H. Keefe, M. Patrick Feeney, Denis F. Fitzpatrick, Li Lin
PurposeThe goals of this study were to measure normal characteristics of ambient and tympanometric wideband acoustic reflectance, which was parameterized by absorbance and group delay, in newborns cared for in well-baby and Neonatal Intensive Care Unit (NICU) nurseries, and to characterize the normal development of reflectance over the first year after birth in a group of infants with clinically normal hearing status followed longitudinally from birth to one year of age.MethodsInfants were recruited from a well-baby and NICU nursery, passed newborn otoacoustic emissions (OAE) and automated auditory brainstem response (ABR) tests as well as follow-up diagnostic ABR and audiometry. They were tested longitudinally for up to one year using a wideband middle ear acoustic test battery consisting of tympanometry and ambient-pressure tests. Results were analyzed for ambient reflectance across frequency and tympanometric reflectance across frequency and pressure.ResultsWideband absorbance and group delay showed large effects of age in the first 6 months. Immature absorbance and group delay patterns were apparent in the low frequencies at birth and one month, but changed substantially to a more adult-like pattern by age 6 months for both ambient and tympanometric variables. Area and length of the ear canal estimated acoustically increased up to age 1 year. Effects of race (African American and others compared to Caucasian) were found in combination with age effects. Mean and confidence intervals are provided for use as a normative longitudinal database for newborns and infants up to one year of age, for both well-baby and NICU infants.



from #Audiology via ola Kala on Inoreader http://ift.tt/1PfLBe3
via IFTTT

Longitudinal development of wideband reflectance tympanometry in normal and at-risk infants

Publication date: Available online 19 December 2015
Source:Hearing Research
Author(s): Lisa L. Hunter, Douglas H. Keefe, M. Patrick Feeney, Denis F. Fitzpatrick, Li Lin
PurposeThe goals of this study were to measure normal characteristics of ambient and tympanometric wideband acoustic reflectance, which was parameterized by absorbance and group delay, in newborns cared for in well-baby and Neonatal Intensive Care Unit (NICU) nurseries, and to characterize the normal development of reflectance over the first year after birth in a group of infants with clinically normal hearing status followed longitudinally from birth to one year of age.MethodsInfants were recruited from a well-baby and NICU nursery, passed newborn otoacoustic emissions (OAE) and automated auditory brainstem response (ABR) tests as well as follow-up diagnostic ABR and audiometry. They were tested longitudinally for up to one year using a wideband middle ear acoustic test battery consisting of tympanometry and ambient-pressure tests. Results were analyzed for ambient reflectance across frequency and tympanometric reflectance across frequency and pressure.ResultsWideband absorbance and group delay showed large effects of age in the first 6 months. Immature absorbance and group delay patterns were apparent in the low frequencies at birth and one month, but changed substantially to a more adult-like pattern by age 6 months for both ambient and tympanometric variables. Area and length of the ear canal estimated acoustically increased up to age 1 year. Effects of race (African American and others compared to Caucasian) were found in combination with age effects. Mean and confidence intervals are provided for use as a normative longitudinal database for newborns and infants up to one year of age, for both well-baby and NICU infants.